{"id":246,"date":"2020-12-04T10:59:34","date_gmt":"2020-12-04T10:59:34","guid":{"rendered":"https:\/\/tmt.newkamikaze.com\/ohkjahuti-osad\/"},"modified":"2022-02-16T15:21:44","modified_gmt":"2022-02-16T13:21:44","slug":"ohkjahuti-osad","status":"publish","type":"page","link":"https:\/\/tmt.newkamikaze.com\/en\/ohkjahuti-osad\/","title":{"rendered":"Parts of Air-cooled heat exchangers"},"content":{"rendered":"<h2>Finned Tubes<\/h2>\n<div align=\"justify\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2790 size-medium alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/finned_tube_main2-e1635170525813-300x170.jpg\" alt=\"\" width=\"300\" height=\"170\" srcset=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/finned_tube_main2-e1635170525813-300x170.jpg 300w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/finned_tube_main2-e1635170525813-768x435.jpg 768w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/finned_tube_main2-e1635170525813.jpg 835w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>Tallinn Machinebuilding Factory (TMT) supplies heat exchange pipes of various types, both as constituent parts of air cooler units and other equipment with this part in their design.<br \/>\nFin pipes offered by <strong>TMT<\/strong> have the following advantages: high heat transfer coefficient, manufacturing quality, as well as mechanical strength achieved by the technology of finning bimetallic pipes by the knurling method. In addition to these advantages, the pipes are well protected against weather-induced corrosion thus ensuring a long service life even in the most unfavourable climatological conditions.<\/p>\n<h2>Casted bonnet<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2571 size-medium alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u043a\u0440\u044b\u0448\u043a\u0430-300x192.png\" alt=\"\" width=\"300\" height=\"192\" srcset=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u043a\u0440\u044b\u0448\u043a\u0430-300x192.png 300w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u043a\u0440\u044b\u0448\u043a\u0430.png 716w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<div>Casted bonnet of split-design chambers for a section of <strong>TMT<\/strong> air-cooled tube units have been working successfully at the factory\u2019s customers for decades.<br \/>\nWe supply casted bonnet on the basis of the available structured database of technical documentation and equipment for the successful manufacture of covers according to any customer\u2019s wishes, both in terms of material design and product dimensions.<\/p>\n<h2>Heat recovery system<\/h2>\n<p>&nbsp;<\/p>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2838 alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/11\/TAK119029.1-300x242.png\" alt=\"\" width=\"300\" height=\"242\" \/>For operation in a cold climate, air cooler heat exchangers are often equipped with heated air recirculation systems in order to prevent overcooling of the product.<br \/>\n<strong>TMT<\/strong> has supply solutions for recirculation systems of both classical and modular design for simplified installation on ACHE.<\/p>\n<h2>Louvres<\/h2>\n<p>&nbsp;<\/p>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2484 alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture7-300x252.jpg\" alt=\"\" width=\"300\" height=\"252\" srcset=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture7-300x252.jpg 300w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture7-768x646.jpg 768w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture7.jpg 877w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<ul>\n<p>Louvres are used for regulating the product temperature, including in heated air recirculation systems, as well as to protect against hydrate formation in gas ACHE. Quality aluminium and steel louvres aid in improving the performance, safety, and energy efficiency of an ACHE.<\/p><\/div>\n<p><strong>TMT<\/strong> has developed louvres systems for ACHE with both manual and pneumatic or electrical control.<\/div>\n<h2><strong>Humidification system<\/strong><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-2493\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture10-300x189.jpg\" alt=\"\" width=\"300\" height=\"189\" srcset=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture10-300x189.jpg 300w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture10-768x483.jpg 768w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/09\/Picture10.jpg 1012w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<div>Air cooler heat exchangers may be equipped with an air humidifier necessary to relieve maximum loads during summertime. To reduce the air temperature, the air is humidified by injecting water mist into the air stream. This system allows increasing the intensity of heat exchange in the ACHE, by lowering the temperature of the incoming air.<br \/>\nMoreover, <strong>TMT<\/strong> can offer an irrigation system for ACHE, where the heat exchange is intensified through the purified water getting on the pipe sections of the ACHE, followed by the collection of wastewater, thus preventing the soil erosion at customers\u2019 facilities.<\/p>\n<h2>Fan blocks<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-2603\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/Capture-\u0432\u0435\u043d\u0442\u0438\u043b\u044f\u0446\u0438\u043e\u043d\u043d\u044b\u0439-\u0431\u043b\u043e\u043a-300x238.jpg\" alt=\"\" width=\"300\" height=\"238\" \/><\/p>\n<div>Often, when revising heat exchange sections and increasing the heat exchange area, customers do not pay due consideration to the possibility of increasing the productivity of the unit by replacing the fan module.<br \/>\nModern lightweight and efficient impellers both reduce energy consumption and significantly outperform impellers of older constructions.<br \/>\nOur offered gear drives have high efficiency and require minimal maintenance, V-belt drives at a low cost are durable, inexpensive and easy to use, the latest low-speed electric motors have increased efficiency with reduced size and weight.<br \/>\nA collector with smooth contours adds up to 10% to the fan module\u2019s performance, a modern-design diffuser and collector do not require the engine frame to be tied to the supporting structures. There is an abundance of similar solutions for creating leading and innovative ventilation units.<br \/>\n<strong>TMT<\/strong> works in constant collaboration with specialised institutes, direct equipment operators and leading world manufacturers in order to find and implement the best ideas.<\/p>\n<h2>Impellers<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2647 alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u0432\u0435\u043d\u0442-300x214.png\" alt=\"\" width=\"243\" height=\"173\" srcset=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u0432\u0435\u043d\u0442-300x214.png 300w, https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u0432\u0435\u043d\u0442.png 608w\" sizes=\"auto, (max-width: 243px) 100vw, 243px\" \/><\/p>\n<div><strong>TMT<\/strong>, for both employing in their own products and for supplying to our customers, has been successfully using extruded aluminium (ALU) and fibre-reinforced polymer (FRP) impellers manufactured by our Italian partners, Ilmed Ventilazione Srl, for many years.<br \/>\nIlmed impellers are designed to ensure maximum reliability and performance throughout their entire service life.<\/p>\n<h2>Gearboxes<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2722 alignright\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/\u0440\u0435\u0434\u0443\u043a\u0442\u043e\u0440\u044b-2\u0432\u0430\u0440-300x154.jpg\" alt=\"\" width=\"300\" height=\"154\" \/><\/p>\n<div>One of the most reliable and effective ways of transferring rotation from an electric motor to the impeller is a geared transmission.<br \/>\n<strong>TMT<\/strong> has long-term relationships with leading manufacturers of reduction units from all over the world and uses these products in their own air cooler heat exchangers.<br \/>\n<strong>TMT<\/strong> successfully finds the best solutions for our esteemed customers for ACHE drives, evaluating the production peculiarities, climatic performance, budget and the customer\u2019s wishes.<\/p>\n<h2>Frequency converters<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-2674 size-medium\" src=\"https:\/\/tmt.newkamikaze.com\/wp-content\/uploads\/2021\/10\/Capture-Configurator-262x300.jpg\" alt=\"\" width=\"262\" height=\"300\" \/><\/p>\n<div><strong>\/&gt;TMT<\/strong> works in collaboration with leading manufacturers of frequency converters. Frequency converters allow regulating the rotation speed of an electric motor by changing the input frequency.<br \/>\nThe introduction of frequency converters into production and automation systems that use them lead to a significant increase in the economic and operational efficiency of air cooler heat exchangers.<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Finned Tubes Tallinn Machinebuilding Factory (TMT) supplies heat exchange pipes of various types, both as constituent parts of air cooler units and other equipment with this part in their design. Fin pipes offered by TMT have the following advantages: high heat transfer coefficient, manufacturing quality, as well as mechanical strength achieved by the technology of [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-content.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-246","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/pages\/246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/comments?post=246"}],"version-history":[{"count":52,"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/pages\/246\/revisions"}],"predecessor-version":[{"id":3030,"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/pages\/246\/revisions\/3030"}],"wp:attachment":[{"href":"https:\/\/tmt.newkamikaze.com\/en\/wp-json\/wp\/v2\/media?parent=246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}